• C100

    Dual sided capacitance double sheet detection / thickness gauging with integrated temperature probe of metals, 0.2 ... 16 mm

  • C100-10S

    C100-10S

    Dual Head Double Sheet Detection

    Double Sheet Control: 0.2 ... 3.5 mm thickness

    Double Sheet Control: 0.2 ... 8 mm thickness

  • C100 - Zweiseitige Doppelblecherkennung

    C100-20S

    Dual Head Double Sheet Detection

    Double Sheet Control: 0.4 ... 7 mm thickness

    Double Sheet Control: 0.4 ... 16 mm thickness

When feeding sheets automatically, more than one sheet can be inadvertently fed into the processing machine. This can result in damage of the machine and tools, expensive repairs and production loss. The dual probe Double Sheet Detector C100-S has been designed to prevent such events.

  • Dual sided capacitance double sheet detection / thickness gauging with integrated temperature probe
  • Noncontact measurement of metals
  • No Teach-In required for thickness gauging
  • Nominal thicknesses are easily entered by key operation or via control input
  • LCD display of nominal and actual values as well as operational and fault messages
  • Sensors and control electronics in one integrated enclosure, quick disconnect, protection class IP54
Technology: Capacitive
Sensor: C100-10SC100-20S
Messbereich:
Steel magn. [FE] 0.2 ... 3.5 mm0.4 ... 7 mm
Aluminum [NF] 0.2 ... 3.5 mm0.4 ... 7 mm
Stainl. steel aust. [NF] 0.2 ... 3.5 mm0.4 ... 7 mm
Non-metals ----
Air gap: 10 mm20 mm
Paricularity: Double Sheet Detection and Thickness MeasurementDouble Sheet Detection and Thickness Measurement
Meas. time: 500 ms500 ms
Applications: Material-independent Double Sheet Detection
Material +  thickness: Electrically conductive sheet from 0.2 ... 16 mm
Meas. method: Double sided / dual sided pair of sensors / sensors
Function principle: 2 sensors, capacitive
Programs: 1 measurement program, memory storage
Switching thresholds: 80% and 150% of nominal value
Special features: Nominal thicknesses are easily entered by key operation or via control input.
  LCD display of nominal and actual values as well as operational and fault messages.

Üste