I10KV

  • Pharma Blister

    Système de capteur inductif I10 KV. Vérification sans contact si le nombre correct de plaquettes alvéolées en aluminium est dans l'emballage fermé.

     

     

During the automatic filling of tablet packages with blister strips in the cartoner -- aluminum blisters, alu-alu blisters -- packages can be overfilled or underfilled. Content verification is therefore absolutely necessary. In comparison to the traditional use of checkweighers, the Roland blister comparator I10 KV is based on the inertia free high speed eddy current measurement principle and requires only approximately 100 mm space in the transportation belt.

  • Up to 10 aluminium foil blisters in a package
  • Programmable for 255 different package sizes
  • Maximum package height 100 mm
  • Minimum blister size 30 x 60 mm in the transportation direction
  • Calibration with a teach-In procedure
Technology: Eddy Current
Blisterpackage:
- Number: Up to 10 Aluminum blister / package
- Area: Min. 30 x 60 mm Blister area
- Height: Max. 100 mm Package height
- Others: As well as Alu / PVC Blister and Alu / Alu Blister
Programs: 255
Velocity: 500 Pck / min