E20

Applications

  • Single probe air gap tolerant double sheet detector of ferrous materials
  • No force after measurement
  • Exchangeable sensors for sheet thickness from 0.1 to 12 mm.
  • Optional: Version 4P allows the connection of up to four double blank sensors

Features

  • Calibration without sheet samples
  • Digital display of sheet thickness and operations parameterm
  • Programmable for 255 different sheet thicknesses
  • Monitoring of over gauge and under gauge limits
  • Monitoring of operating voltage and measurement time
  • PLC interface
  • Optional fieldbus interfaces: Profibus, DeviceNet, ControlNet, Interbus, CANopen, Profinet 
  • Selectable interfaces:
    • Data communication via optional opto coupled RS 232 interface (download)
    • Relay or opto coupled output for under gauge, nominal gauge, over gauge, and enable
  • Optional: Wall enclosure (IP65) or front panel mounting

Device variation

  • to the connection of a sensor
  • to the connection from up to 4 sensors

Technical data

Applications: Double sheet detection in vacuum destacker, robot loader,
press feeder
Material thickness: Steel: 0.1 - 12 mm (.004 - .472 in)
Measuring method: single probe double sheet detection
Functional principle: Electromagnetic double sheet sensor
Programs: 255 measurement programs possible
Special features: Linearized air gap tolerant double sheet sensors
Up to four double sheet sensors of the same type can be connected (Version 4P)
Short measurement cycles