• UDK20

    Single Side Double Sheet Control

    Sheet thickness up to 4 mm single sheet thickness of ferrous and non-ferrous materials (automotive aluminium alloy), stainless steel austenite up to 2 mm.

    Device variatons for connecting up to 2 sensors, via switch box up to 4 sensors.

Single probe double sheet control up to 4 mm single sheet thickness (up to 0.160in.) of ferrous and non-ferrous materials (automotive aluminium alloy), stainless steel austenite up to 2 mm.

  • Electro magnetic and eddy current principles integrated in one sensor
  • Digital display of sheet thickness and operations parameter
  • Programmable for 255 different sheet thicknesses
  • Monitoring over gauge and under gauge limits
  • Monitoring of operating voltages and measurement times
  • PLC interface Optional fieldbus interfaces: Profibus, DeviceNet, ControlNet, Interbus, CANopen, ProfiNet
  • Selectable interfaces:
    - Data communication and data back up via optional opto coupled
    - Relay or opto coupled output for under gauge, nominal gauge, over gauge and enable
  • Optional wall mount enclosure (IP65) or font panel mounting
    • UDK20-2PW-B-R-S: Control from the PLC, Relais version
    • UDK20-2PW-B-O-S: Control from the PLC, Opto coupler version
    • UDK20-2PW-C-O-S: Data backup, Control from the PLC, Opto coupler version
    • UDK20-2PW-PR-S*: Data backup, Control from the Profibus

    * among Profibus all common fieldbus systems are available.

    Technology: Inductive
    Sensor: PW42AGS
    Meas. range:
    Steel magn. [FE] 0,2 ... 4 mm
    Aluminum [NF] 0,2 ... 4 mm
    Stainl. steel aust.[NF] 0,2 ... 2 mm
    Non-metals --
    Air gap: 0 mm
    Particularity: Electromagnet and eddy current principles integrated in one sensor
    Meas. time: 80 ms
    Applications: Single probe double sheet detection in vacuum destacker, robot loader. Suitable for steel and aluminum.
    Material + Thickness:

    FE-Material: up to 4 mm

    NF-material: up to 4 mm (up to .16 in) depending on the type of material (austenite up to 2 mm)

    Meas. method: Single probe double sheet detection
    Function principle: Electromagnetic Eddy current
    Programs: 255 Measuring programs possible
    Particularities: Electromagnet and eddy current principles integrated in one sensor

    To top