When feeding sheets automatically, more than one sheet can be inadvertently fed into the processing machine. This can result in damage of the machine and tools, expensive repairs and production loss. The dual probe Double Sheet Detector C100-S has been designed to prevent such events.
| C100-10S: | |
| Double Sheet Detection: | 0.2 to 3.5 mm |
| Sheet Thickness Gauging: | 0.2 to 8.0 mm |
| C100-20S: | |
| Double Sheet Detection: | 0.4 to 7.0 mm |
| Sheet Thickness Gauging: | 0.4 to 16.0 mm |
| Applications: | material-independent double sheet detection |
| Material thickness: | electrically conductive sheet from 0.2 to 16 mm |
| Measuring method: | double sided / dual sided pair of sensors / sensors |
| Functional principle: | 2 sensors, capacitance |
| Programs: | 1 measurement program, memory storage |
| Switching threshold: | 80% and 150% of nominal value |
| Special features: | Nominal thicknesses are easily entered by key operation or via control input. LCD display of nominal and actual values as well as operational and fault messages. |